*(It need to check the boiler condition annually and every non eletric part annually.)
These boilers are easy and economical to operate. Their firebox is made of 5 mm thick steel by welding folded edges. The 3 boiler doors are made of cast iron to satisfy all necessary operational functions (filling, cleaning, air control). These boilers have one firebox behind the middle door.
Advantages of Celsius V and P-V classic solid boilers:
- The classic boilers provide even heat distribution in a Celsius Heating System, whether used on its own or with open fireplaces or stoves.
- Uses renewable energy.
- Classic boilers produce useable energy from non-woody biomass.
- If required, coal can be used as a source of fuel.
- Firebox and internal frame are 5 mm thick resistant steel for durability and high pressure tolerance.
- Operation is easy and economical.
- Able to heat with other boiler or heat source (maximum of 2 bar pressure) in the one heating system.
- Suitable for radiator, underfloor or combined heating system.
- Able to produce drinkable hot water with domestic hot water package.
- These boilers are easy and economical to operate. Their firebox is made of 5 mm thick steel by welding folded edges. The 3 boiler doors are made of cast iron and satisfy all necessary operational functions (filling, cleaning, air control). These boilers have one firebox behind the middle door.
RECOMMENDED FUELS:
• Non-woody biomass
ACCESSORIES:
• Boiler thermometer
• Filling/draining tap
• Fire grates (grills)
OPTIONAL ACCESSORIES:
- Automatic draught regulator
- Security valve (2 bar)
- Pump heating system in case of pump system controller
- Heating system controllers
- Celsius anticondensing unit package up to 65 kW
- Celsius safety heat exchanger (to avoid overheating)
- Stainless steel chimney system
- Slag scraper, ashpan
TECHNICAL SPECIFICATIONS |
|
Modul |
P-V 30 |
Firing door size (mm) |
300*300 |
Maximum heat output (kW) |
27 |
Heating-system dependant heatable air-space(m3) |
300-770 |
Fuel-dependant efficiency (%) |
78-82 |
Heating water connection (") |
2" |
Uptake connection (mm) |
132 |
Height (mm) |
1150 |
Width (mm) |
480 |
Depth (mm) |
550 |
Weight (kg) |
194 |
Water volume (l) |
56 |
Max. operating pressure (bar) |
2 |
Max. operating temperature (°C) |
90 |
Test pressure (bar) |
4 |
Firebox size (mm) (height*width*depth) |
500*355*405
|
Mark
|
Description
|
A
|
Height of boiler
|
B
|
Width of boiler
|
C
|
Depth of boiler
|
D
|
Cleaning door
|
E
|
Firing door
|
F
|
Secondary draught regulator slot
|
G
|
Ash removal door (primary draught regulator)
|
I
|
Forward water connection
|
J
|
Return water connection
|
K
|
Uptake connection
|
L
|
Automatic draught regulator connection
|
M
|
Manual and automatic draught regulator option
|
N
|
Filling/draining tap connection
|
O
|
Boiler thermometer connection
|