The T6 controller controls a floor central heating system (CH). In addition to switching the actuators mounted on the mixing valves of the CH floor system on and off, the controller can also switch off the CH boiler and the circulation pump when all heating circuits are switched off. The controller can work with wired EUROSTER room thermostats and normally closed (NC) valve drives with 230 VAC in CH circuits.
Controlled devices |
valve drives, central heating pump, boiler |
Power supply |
230 V 50 Hz |
Nominal output load (combined) |
3 A 230 V 50 Hz |
Nominal power consumption |
1,7 W |
Status visualization |
LED diodes |
Operating temperature range |
+5°C...+40°C |
Storage temperature range |
0°C...+65°C |
IP rating protection class |
IP 40, class II against electric shocks |
Color |
White |
Mount method |
wall bracket, wall plug or DIN rail |
Weight (including power cord) |
0,356 kg |
Certification |
Standards correspond to the EMV and LVD guidelines |
Guarantee |
2 Years |
Dimensions (W / H / D) mm |
270/97/50 |
Packing list |
Euroster T6 230 V controller, sockets, instructions |